Ope
rating Instructions
Electronics module
VEGADIF 65
Document ID:
36132
Diere
ntial pressure
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Electronics module

Operating InstructionsElectronics moduleVEGADIF 65Document ID:36132Differential pressure

Página 2

6 Maintain6.1 Instrument repairIf a repair is necessary, please proceed as follows:You can download a return form (23 KB) from our Internet homepageww

Página 3 - 1.3 Symbolism used

7 Dismounting7.1 Dismounting stepsTake note of chapters "Mounting" and "Connecting to power supply"and carry out the listed steps

Página 4 - 2.2 Appropriate use

8 Supplement8.1 Technical dataTechnical datacan be found in the operating instructions manual of the respective sensor.12 Electronics module • VEGADIF

Página 5 - 3 Produc

Electronics module • VEGADIF 65 138 Supplement36132-EN-091210

Página 6 - 4.3 Mounting steps

14 Electronics module • VEGADIF 658 Supplement36132-EN-091210

Página 7

Electronics module • VEGADIF 65 158 Supplement36132-EN-091210

Página 8

VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermanyPhone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected] date:ISO 9

Página 9 - 5.1 Setup

Contents1 About this document1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2 Target group . . . . . . . . . . . .

Página 10 - 6.1 Instrument repair

1 About this document1.1 FunctionThis operating instructions manual has all the information you need forquick mounting and setup of a replacement modu

Página 11 - 7 Dismou

2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manual must becarried out only by trained specialist

Página 12 - 8.1 Technical data

3 Product description3.1 ConfigurationThe scope of delivery encompasses:l VEGADIF 65 electronics modulel Documentation- this operating instructions man

Página 13 - 36132-EN-091210

4 Mounting4.1 General instructionsThe pressure transmitters VEGADIF 65 are equipped with a two-partelectronics: the meas. cell and the processing elec

Página 14

1Fig. 1: Singlechamber1 Position of the electronics compartment1Fig. 2: Doublechamber housing1 Position of the electronics compartmentProceed as follo

Página 15

21Fig. 3: Looseningthe holding screws1 Electronics module2 Screws (2 pcs.)5 Pull the previous electronics out by holding the opening levers.Note:Make

Página 16 - ISO 9001

5 Setup5.1 SetupAftermounting a new electronics module and connecting to powersupply, the following data are loaded automatically from the meas. celle